Ürünlerimiz

ULTRASONİK BANYO - SONİKATÖR
ULTRASONİK BANYO - SONİKATÖR
ULTRASONİK BANYO
|
SUPER RK …
|
DIGITEC DT … |
DIGIPLUS DL … |
Capacity (L) |
0.9 – 90.0 |
0.9 – 90.0 |
3.0 – 28.0 |
Time setting (min) |
1–15, ± 5 % continuous operation (∞) |
1, 2, 3, 4, 5, 10, 15, 30, ± 5 % continuous operation (∞) |
1, 2, 3, 4, 5, 10, 15, 30, ± 5 % continuous operation (∞) |
Safety shut-down |
No |
after 12 hours |
After 12 hours |
Heating |
Optional, version „H“ |
Optional, version „H“ |
3 |
Adjustable temp.range (oC) |
30 – 80 RK 31 H : 65 fixed |
20 – 80 |
20 – 80
|
Excess temp. signal |
No |
Yes |
Yes |
Protection aganist boiling retardation |
No |
Yes |
Yes |
Setting accuracy of bath temp. (K) |
± 5 K |
± 2.5 K |
± 2.5 K |
Thickness tank (mm) / material C-version : |
0.8 / 1.4301 2.0 / 1.4404 |
0.8 / 1.4301 2.0 / 1.4404 |
0.8 / 1.4301
|
Filling mark for safe dosage |
Yes |
Yes |
Yes |
Hard chromium-plated |
RK 102 H |
DT 102 H / H-RC |
DL 102 H |
One-piece drain, welded |
Yes , from RK 102 H |
Yes , from DT 102 H |
Yes |
Degree of protection |
IP 32 |
IP 33 |
IP 33 |
Ultrasonic frequency (kHz) |
35 |
35 |
35 |
SweepTec |
Yes |
Yes |
Yes |
Pulse function |
Yes |
Yes |
Yes |
Power setting |
No |
No |
20 – 100 % in 10 % steps |
Oscillating systems |
Yes |
Yes |
Yes |
Fast degassing DEGAS |
No |
Yes |
Yes |
Mains supply: 230 V - (+- 10%) 50/60 Hz 115 V – (+-10%) 50/60 Hz |
Yes |
Yes |
Yes |
Data memory |
No |
No, Type H-RC: WINSONIC®software |
No
|
Interface / PC software |
No |
RS 232 bei Typ H-RC /3 |
No |
Medical device class I |
Yes |
Yes |
No |
ULTRASONİC SONİKATÖR
|
SERİE 4000
|
MİNİ20 |
SERİE 2000.2 |
|
ADVANCED |
SPECİAL |
BASIC |
Sample volumes Batch Flow-through |
0.5 to 1000 ml. Up to 30 l / h |
0.1 to 25 ml. |
1 to 1000 ml. Up to 30 l / h |
Ultrasonic converter |
Possible configurations: GM 4100 with UW 50 or UW 100 and SH 100 G
GM 4200 with UW 50 or UW 200 with SH 200 G
GM 4400 with UW 400 and SH 400 G or with UW 200 and SH 200 G |
1 |
1 |
Amplitude setting |
10 to 100 % |
10 to 100 % |
10 to 100 % |
Automatic amplitude limiting |
After input of the assembled probe |
After input of the assembled probe |
After input of the assembled probe |
Pulsation |
ON cycles 0.2 – 600 s OFF cycles 0.3 – 600 s |
ON cycles 0.1 – 60 s OFF cycles 0.2 – 60 s |
ON cycles 1 – 60 s OFF cycles 1 – 60 s |
Time setting |
9 h : 59 min : 59 s Continuous or timed
|
59 min : 59 s |
59 min : 59 s Continuous or timed
|
Safety shut-down |
9 h : 59 min : 59 s |
59 min : 59 s |
9 h : 59 min : 59 s |
Indicators |
Alphanumerical LC display of amplitüde, pulse level, time, energy input, temperature (optional) |
Alphanumerical LC display of amplitüde, pulse level, time, energy input |
Alphanumerical LC display of amplitüde, pulse level, time |
Energy display |
in kJ |
in kJ |
No |
Temperature display and measurement |
Optional, 0 to 120 oC, Temperature sensor required, alternatively beep or switch off |
No |
No |
Batch operation Sequencing |
Yes, Several batches one after the other |
No |
No |
Remote control with PC |
RS 232 (Sub-D) |
RS 232 (infrared) |
No |
Fault diagnosis |
Yes |
Yes |
Yes |
Operating frequency |
20 kHz |
30 kHz |
20 kHz |
Program memory |
Yes, 9 |
Yes , 9 |
No |
Functional test |
Yes |
Yes |
No |
Mains connection |
230 V-(+- 10%), Alternatively 115 V-(+- 10 %), 50/60 Hz |
100-240 V- , 50 / 60 Hz |
230 V-(+- 10%), Alternatively 115 V-(+- 10 %), 50/60 Hz |